Environmental Requirements

For trouble-free operation of the SDM-9220/9230 its location must satisfy the following
environmental criteria:

Operating temperature: 0

C to 45C (32F to 113F)*

Storage temperature: -20

C to 65C (-4F to 149F)

Relative humidity: 10% to 90%, non-condensing

Maximum operating altitude: 4572 meters (15 000 feet)*

Ventilation requirement: leave 5 cm (2 inches) of unobstructed space around the
unit. All unused slots must be closed with a plate.

* NOTE:

Above 3048 meters (10 000 feet) altitude the maximum operating temperature

of the unit drops from 45°C to 35°C.