beautypg.com

6 e&m interface card, E&m interface card -27, Rj-45 pinout for e&m interface card -27 – Comtech EF Data SDM-9220 User Manual

Page 105: Refer to, Table 5-9

background image

Product Description

Memotec Inc.

5-27

CAUTION:

:

Use a two-wire cable for FXS connections. In rare

circumstances, your telephone or fax may not work if you use a four-
wire cable. Should this occur, replace the four-wire cable with a two-
wire cable
. If the problem persists, contact Technical Support.

NOTE:

You must install a ferrite on each cable connected to an FXS or FXO port

on an SDM-9220 UAC or SDM-9230 UAC installed in the European
Union or Russia.
These ferrites are

not

provided with the SDM-9220/

9230product package. For instructions, turn to

“Installing the Ferrites (EMI

Filters)” on page 4-26

.

5.9.6

E&M Interface Card

Use an RJ-45 cable provided in the product package to make an analog PBX tie-line
connection on an E&M interface card.

This cable is a solid wire cable with 8 conductors and RJ-45 plugs (8 pins) at both ends.
Four RJ-45 to RJ-45 cables are provided for each E&M interface card.

The following table describes the RJ-45 pinout for an E&M port.

NOTE:

The pinout functions on an E&M/PTT port are slightly different from that of a
standard E&M port. Refer to

“Cable and Connector” on page 9-2

.

Pin No.

Usage

Description

1

SB

Signal Battery. Return for M Signal

2

M

Control Signal from PBX

3

R1

Voice from PBX (Transmit Ring)

4

R

Voice to PBX (Receive Ring) two-wire connection

5

T

Voice to PBX (Receive Tip) two-wire connection

6

T1

Voice from PBX (Transmit Tip)

7

E

Control Signal to PBX

8

SG

Signal Ground

Table 5-9: RJ-45 pinout for E&M interface card

This manual is related to the following products: