beautypg.com

2 two remote locations scenario, Two remote locations scenario -7, Push-to-talk application: scenario 2 -7 – Comtech EF Data SDM-9220 User Manual

Page 135: Figure 9-3, Push-to-talk

background image

Universal E&M/PTT Interface Card

Memotec Inc.

9-7

9.3.2

Two Remote Locations Scenario

In an application involving communications with two remote locations (Scenario 2):

The M lead is not permanently connected to Signal Ground at either end of the
connection

The E&M connection goes up and stays up once the first M lead transition
occurs, in other words, when the first user at either location presses the talk but-
ton

Users at both locations can use their radio as a

PTT CONTROL

device, producing

transitions on the M lead which the NetPerformer detects and regenerates as E
lead transitions at the opposite end of the connection.

Table 9-3: Push-To-Talk Application: Scenario 2