4.9 E&M Wiring and Grounding
In a two-wire E&M application, connect wires 4 and 5 to the PBX R and T pair,
respectively. Refer to
•
The R and T pair carry voice/fax analog signals between the SDM-9220/9230
and the PBX.
In a four-wire E&M application, connect wires 4 and 5 to the PBX R and T pair, and wires
3 and 6 to the PBX R1 and T1 pair, respectively.
•
The R and T pair carry voice/fax analog signals from the SDM-9220/9230 to the
PBX.
•
The R1 and T1 pair carry voice/fax analog signals from the PBX E&M tie trunk
to the SDM-9220/9230.
Connect the signaling wires as indicated in the following table:
When PBX-to-PBX E&M tie trunks are installed, the E lead of one PBX is normally
crossed over and connected to the M lead of the other PBX, and vice versa. See the first
connection scenario in
“Four-wire E&M Connections” on page 4-24
application the crossover is accomplished digitally. Therefore, when connecting an analog
PBX to the E&M interface card, the E and M leads of the PBX connect to the E and M
E&M Signaling Type
Pin No.
Connect to PBX Lead
I, V
7
E
2
M
8
SG (common ground)
II
7
E
8
SG
2
M
1
SB
Table 4-2: E&M wiring