Hardware Installation

Memotec Inc.

4-23

4.9 E&M Wiring and Grounding

In a two-wire E&M application, connect wires 4 and 5 to the PBX R and T pair,
respectively. Refer to

Table 5-9

.

The R and T pair carry voice/fax analog signals between the SDM-9220/9230
and the PBX.

In a four-wire E&M application, connect wires 4 and 5 to the PBX R and T pair, and wires
3 and 6 to the PBX R1 and T1 pair, respectively.

The R and T pair carry voice/fax analog signals from the SDM-9220/9230 to the
PBX.

The R1 and T1 pair carry voice/fax analog signals from the PBX E&M tie trunk
to the SDM-9220/9230.

Connect the signaling wires as indicated in the following table:

When PBX-to-PBX E&M tie trunks are installed, the E lead of one PBX is normally
crossed over and connected to the M lead of the other PBX, and vice versa. See the first
connection scenario in

“Four-wire E&M Connections” on page 4-24

. In a multiplexing

application the crossover is accomplished digitally. Therefore, when connecting an analog
PBX to the E&M interface card, the E and M leads of the PBX connect to the E and M

E&M Signaling Type

Pin No.

Connect to PBX Lead

I, V

7

E

2

M

8

SG (common ground)

II

7

E

8

SG

2

M

1

SB

Table 4-2: E&M wiring