beautypg.com

Comtech EF Data CRS-180 User Manual

Page 94

background image

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

MN/CRS180.IOM

Cables and Connections

Revision 11

5–34

CAUTION – It is ESSENTIAL that you make the control and the IF Rx and Tx

connections correctly.

KT/12554 70/140 MHz IF 1:1 Redundancy Kit (CRS180CDM-7190G)

Item CEFD P/N

Qty

Description

1

PL/11560-1

1

Top Assy, CRS-180 70/140 MHz IF 1:1 Redundancy Switch

2

XF/BNC-MF-50-75

Notes 1,2

4

Transformer, 50-75Ω, 2-200 MHz, BNC, M/F

3

PL/0813-4

Note 2

2

Cable, Special, IF BNC, 75Ω

4

PL/0946-1

Note 2

4

Cable, Special, IF BNC, 50Ω

5

CA/WR12135-1

Notes 3,4

2 Cable Assy, Control Adapter RoHS-Compliant

Figure 5-29. CDM-710G Switch-to-Modem Control & IF Connections (CEFD Kit KT/12554)