CRS-180 70/140 MHz IF 1:1 Redundancy Switch

MN/CRS180.IOM

Modem and Switch Configuration

Revision 11

4–11

4.4.1 CDM-570/A Non-IP Redundancy Configuration

Do these steps for setup of CDM-570/A modems for 1:1 Redundancy, when the terrestrial data

type is non-Ethernet (i.e. RS422, G.703):

Step

Task

1

Enable 1:1 Redundancy on both modems:

From the CLI Main Menu, press ‘E’ to open the 1:1 Redundancy Configuration page.

o

Press ‘R’ to toggle 1:1 Redundancy as [Enabled].

o

Press ‘S’ to ““Save Parameters to permanent storage”.

Alternately, using the HTTP (Web Server) Interface ‘REDUNDANCY’ page:


o

Use the drop-down list in the 1:1 Redundancy Control section of this page to select

Enabled.

o

Click [Submit] to save.

If you submit any changes to this web page when the CDM-570A optional IP

Packet Processor is INSTALLED, you must also open the ‘Admin | Pap Save’

page and immediately click [Save PaP Parameters].

2

Connect all cables to the modems and the CRS-180. This includes the control cable, IF cable and

data ‘Y’cables.

Chapter 5. CABLES AND CONNECTIONS