beautypg.com

1 asi 75ω data interface (cdi-40) kit kt/12579 – Comtech EF Data CRS-180 User Manual

Page 102

background image

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

MN/CRS180.IOM

Cables and Connections

Revision 11

5–42

5.6.2.1.1 ASI 75Ω Data Interface (CDI-40) Kit KT/12579

Figure 5-36 shows an example of a CDM-710 1:1 modem configuration with the CDI-40 ASI Data

Interface installed in Slot 1, with Slot 2 empty. The figure depicts installation of one KT/12579

ASI Interface Kit.

Be sure to connect to the lower BNC connector pair labeled “1:1” on the CDI-40 ASI

Data Interface. The Rx port on each interface has been tuned to be 3 dB higher

amplitude to compensate for the presence of the RF/SA32KC-IN/OUT 2-way

combiner.

KT/12579 ASI (CDI-40) 75 Interface Kit

CEFD P/N

Qty Description

CA/BNC75OHM

4

Cable – IF BNC, 75Ω, 1’

RF/SA32KC-IN/OUT

2

Combiner – 2-way w/Bracket, 0.25-300 MHz, 75Ω BNC

Figure 5-36. CDM-710 CDI-40 ASI 1:1 Example