CRS-180 70/140 MHz IF 1:1 Redundancy Switch

MN/CRS180.IOM

Switch Connectors and Pinouts

Revision 11

3–5

3.2.1.2 J3 | Control A’ Connector (Top) – Modem ‘A’ (DB-9F)

The Modem ‘A’ Control connector is a 9-pin Type ‘D’ female interface. Pins 2, 3,

and 4 carry signals looped through the switch module from Modem ‘B’ to Modem

‘A’, while pins 6, 7, and 8 loop the same signals from Modem ‘A’ through to

Modem ‘B’. The 12VDC input, which is diode OR’ed with the corresponding 12VDC

input from Modem ‘B’, powers the switch module.

Table 3-2. ‘J3 | Control A’ Modem Connector Pinouts

Pin Signal Name

Signal Function

Direction

5

Ground

Signal Ground

-

9

+12VDC

+12 VDC

In

4

ONLINE_OUT_B

Modem ‘B’ Online Indication

Out

8

/FAIL_OUT_A

Modem ‘A’ Fault Indication

In

3

ONLINE_OUT_B

Modem ‘B’ Online Indication

Out

7

ONLINE_OUT_A

Modem ‘A’ Online Indication

In

2

AUX_SER_TX_B

Modem ‘B’ Serial Tx

Out

6

AUX_SER_TX_A

Modem ‘A’ Serial Tx

In

1

Ground

Signal Ground

-

3.2.1.3 ‘J4 | Control B’ Connector (Bottom) – Modem ‘B’ (DB-9F)

The Modem ‘B’ Control connector is a 9-pin Type ‘D’ female interface. Pins 2, 3,

and 4 carry signals looped through the switch module from Modem ‘A’ to Modem

‘B’, while pins 6, 7, and 8 loop the same signals from Modem ‘B’ through to

Modem ‘A’. The 12VDC input, which is diode OR’ed with the corresponding 12VDC

input from Modem ‘A’, powers the switch module.

Table 3-3. ‘J4 | Control B’ Modem Connector Pinouts

Pin Signal Name

Signal Function

Direction

5

Ground

Signal Ground

-

9

+12VDC

+12 VDC

In

4

/FAIL_OUT_A

Modem ‘A’ Fault Indication

Out

8

/FAIL_OUT_B

Modem ‘B’ Fault Indication

In

3

ONLINE_OUT_A

Modem ‘A’ Online Indication

Out

7

ONLINE_OUT_B

Modem ‘B’ Online Indication

In

2

AUX_SER_TX_A

Modem ‘A’ Serial Tx

Out

6

AUX_SER_TX_B

Modem ‘B’ Serial Tx

In

1

Ground

Signal Ground

-