beautypg.com

4 summary of specifications – Comtech EF Data CRS-180 User Manual

Page 34

background image

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

MN/CRS180.IOM

Introduction

Revision 11

1–14

1.4 Summary of Specifications

Equipment Type

IF 1:1 Redundancy Switch

Manufacturer

Comtech EF Data, Tempe, Arizona

Comtech EF Data

Modems Supported

CDM-625A Advanced Satellite Modem

CDM-625 Advanced Satellite Modem

CDM-760 Advanced High-Speed Trunking Modem

CDM-750 Advanced High-Speed Trunking Modem

CDM-570A 70/140 MHz Satellite Modem (with/without Optional IP Packet

Processor)

CDM-570 70/140 MHz Satellite Modem (with/without Optional IP Module)

CDM-710G 70/140 MHz High-Speed Satellite Modem

CDM-710 70/140 MHz Broadcast Satellite Modem

CDM-700 70/140 MHz Satellite Modem

Operating Modes

Fully Automatic under control of supporting 1:1 switch.

Manual under control of supporting 1:1 switch.

Architecture

Full bridging architecture with configuration synchronization.

Tx switching guarantees the Offline modem is muted at least 60 dB down.

Rx IF signal fed to both Online and Standby units.

Switch Conditions

Tx/Rx switching follows state of supporting data switching via control input from data

switch.

IF Switching/

Splitting

Tx IF: Switched by RF relay (1.5 dB max loss, 40 dB min ON/OFF isolation)

Rx IF: Passive power splitting (4dB max loss)

Tx-Rx Isolation

40 dB min, 50 - 190 MHz

IF Impedance

Optimized for 50Ω (> 10 dB return loss on external IF ports), 75Ω supported with the

use of external RF transformers (included).

IF Connectors

50Ω BNC Female

IF Frequency Range

50 to 190 MHz

Weight

1.1lbs (0.5kg)

Dimensions

Excluding connectors: 1.7 H x 5.7 W x 4.1 D inches (43 H x 143 W x 104 D mm)

Optional 19-inch rack mounting kit available (CEFD P/N KT/11708)

Power requirements

1 Watt maximum

+12 volts DC @ 80 mA (max)

(Power supplied by modems)

Approvals

‘CE’ as follows:

EMC

Safety