4 summary of specifications – Comtech EF Data CRS-180 User Manual
Page 34

CRS-180 70/140 MHz IF 1:1 Redundancy Switch
MN/CRS180.IOM
Introduction
Revision 11
1–14
1.4 Summary of Specifications
Equipment Type
IF 1:1 Redundancy Switch
Manufacturer
Comtech EF Data, Tempe, Arizona
Comtech EF Data
Modems Supported
•
CDM-625A Advanced Satellite Modem
•
CDM-625 Advanced Satellite Modem
•
CDM-760 Advanced High-Speed Trunking Modem
•
CDM-750 Advanced High-Speed Trunking Modem
•
CDM-570A 70/140 MHz Satellite Modem (with/without Optional IP Packet
Processor)
•
CDM-570 70/140 MHz Satellite Modem (with/without Optional IP Module)
•
CDM-710G 70/140 MHz High-Speed Satellite Modem
•
CDM-710 70/140 MHz Broadcast Satellite Modem
•
CDM-700 70/140 MHz Satellite Modem
Operating Modes
•
Fully Automatic under control of supporting 1:1 switch.
•
Manual under control of supporting 1:1 switch.
Architecture
•
Full bridging architecture with configuration synchronization.
•
Tx switching guarantees the Offline modem is muted at least 60 dB down.
•
Rx IF signal fed to both Online and Standby units.
Switch Conditions
Tx/Rx switching follows state of supporting data switching via control input from data
switch.
IF Switching/
Splitting
•
Tx IF: Switched by RF relay (1.5 dB max loss, 40 dB min ON/OFF isolation)
•
Rx IF: Passive power splitting (4dB max loss)
Tx-Rx Isolation
40 dB min, 50 - 190 MHz
IF Impedance
Optimized for 50Ω (> 10 dB return loss on external IF ports), 75Ω supported with the
use of external RF transformers (included).
IF Connectors
50Ω BNC Female
IF Frequency Range
50 to 190 MHz
Weight
1.1lbs (0.5kg)
Dimensions
Excluding connectors: 1.7 H x 5.7 W x 4.1 D inches (43 H x 143 W x 104 D mm)
Optional 19-inch rack mounting kit available (CEFD P/N KT/11708)
Power requirements
1 Watt maximum
+12 volts DC @ 80 mA (max)
(Power supplied by modems)
Approvals
‘CE’ as follows:
•
EMC
•
Safety