Comtech EF Data OM20 User Manual
Page 78
OM20 Universal Outdoor Modem
Web Browser/Remote Protocol
MN-OM20– Revision 5
6–4
6
Product Information
Contact Information
Access to technical trouble-shooting,
product options and specifications is
accomplished by selecting one and clicking
on that function. Contact Radyne via Email
by clicking on “Contact Us”.
6.2.3 LED Indicators
Twelve LEDs on the OM20 GUI Interface (Refer to Table 6-2) indicate the status of the OM20’s
operation. The LED colors maintain a consistent meaning. Green is appropriate for normal
operation, Yellow means that there is a condition not proper for normal operation, and Red
indicates a fault condition that will result in lost communications.
Table 6-2.
LED
Color
Function
Modem LED Indicators
Power
Green
Indicates that the unit is turned on.
Fault
Red
Indicates a hardware fault for the unit.
Event
Yellow
Indicates that a condition or event has occurred that the
modem has stored in memory. The events may be viewed
from the GUI or in the Terminal Mode.
Remote
Green
Indicates that the unit is in the process of updating firmware
with FTP.
Modulator LED Indicators
Transmit On
Green
Indicates that the Modulator transmitter is on.
Major Alarm
Red
Indicates that the Transmit Direction has failed, losing
traffic.
Minor Alarm
Yellow
Indicates that a Transmit Warning Condition exists.
Test Mode
Yellow
Indicates that the transmitter is involved in a current Test
Mode activity.
Demodulator LED Indicators
Signal Lock
Green
Indicates that the receiver locked to an incoming carrier and
data, including FEC Sync.
Major Alarm
Red
Indicates that the Receive Direction has failed, losing traffic.
Minor Alarm
Yellow
Indicates that a Receive Warning Condition exists.
Test Mode
Yellow
Indicates that the receiver is involved in a current Test Mode
activity.