Comtech EF Data OM20 User Manual

Page 115

background image

OM20 Universal Outdoor Modem

Web Browser/Remote Protocol

MN-OM20– Revision 5

6–41

BUFFER CLOCK CONTROL

Buffer Size (msec):

{0 - 64 msecs}

Allows the user to set the Doppler Buffer Size in msec.



Buffer Clock Polarity:

{NORMAL, INVERTED}

Allows the user to select the Buffer Clock Polarity for the Tx
Terrestrial Clock relative to the Tx Data. If G.703 Interface is
selected, this selection cannot be changed.


Number of Buffer Sources:

{1 – 5}

Allows the user to select up to 5 clock sources.


Active Buffer Clock:

{RXSAT, EXTBNC, SCTE, SCT, EXT IDI}

Shows the current active buffer clock source.



BUFFER CLOCK SOURCES


Source 1 of 1:

{SCTE, SCE, RX SAT, EXT BNC, EXT IDI}


Source 2:

{SCTE, SCE, RX SAT, EXT BNC, EXT IDI}


Source 3:

{SCTE, SCE, RX SAT, EXT BNC, EXT IDI}


Source 4:

{SCTE, SCE, RX SAT, EXT BNC, EXT IDI}


Source 5:

{SCTE, SCE, RX SAT, EXT BNC, EXT IDI}


RX ASYNC

Async Mode:

{ES-ES, ESC ENHANCED}

ES-ES is displayed when IBS Network Spec is selected. ESC
Enhanced can be selected in Closed Net and uses the Overhead
Signaling bytes in the IBS Overhead to pass asynchronous data.
This menu is not available when SCC is selected.


ES Interface:

{RS-232, RS-485}

Allows the user to select the interface type.


ES Baud Rate:

{150 – 1024} For IBS ES to ES

{150 – 19200} For ES to ES Enhanced

{150 – 115200} For SCC Communications

ES to ES : Fixed Baud Rate based on IBS Network
Specification.
Available rates are listed in Table 3-3.