RX Setup Menu

Figure 6-19. RX Setup Menu


Circuit ID:

Provides entry of Rx Circuit Identifier. Circuits can be given up
to an 11 Character alphanumeric Identity such as DLINK1


Terrestrial Streaming:

{BYTE OUTPUT, PACKET OUTPUT} ASI only

Byte output = continuous

Packet output = burst

Terrestrial Interface:

{RS422 SERIAL, G.703 T2 UNBAL, G.703 E1 BAL, G.703
E1 UNBAL, G.703 T1 AMI, G.703 T1 B8ZS, V.35,
ETHERNET}

Allows the user to select the Receive Type.


Esc Ch. 1 Gain

Provides gain in channel 1of engineering service channel in 96K
framing mode.

Esc Ch. 2 Gain

Provides gain in channel 2 of engineering service channel in 96K