Notes on the Documentation

Fieldbus Components

81

Setting via UserPrmData

The Bus Coupler's reset is carried out automatically if the DP buffers are set using UserPrmData:

Byte Bit Description

12

4-
7

15 dec or 0xF hex: the maximum DP buffer lengths are changed using the values from
UserPrmData 37-40

37

0-
7

maximum length of input data

38

0-
7

maximum length of output data

39

0-
7

maximum length of diagnosis data

40

0-
7

maximum length of configuration data

Example 1: Not enough configuration data

128 bytes input

128 bytes output

80 bytes CfgData

48 bytes diagnosis data

Example 2: Not enough input data

160 bytes input

96 bytes output

64 bytes CfgData

64 bytes diagnosis data