Notes on the Documentation

Fieldbus Components

79

Enabling/disabling via the 2-byte PLC interface or through KS2000

The terminals are enabled or disabled through table 1, registers 0-31:

Register

Bit

Description

0,1

Assignment for terminal 1
0: DP DataExchange (default)
2: disabled (Multi-Config mode)

2,3

Assignment for terminal 2
0: DP DataExchange (default)
2: disabled (Multi-Config mode)

4,5

Assignment for terminal 3
0: DP DataExchange (default)
2: disabled (Multi-Config mode)

6,7

Assignment for terminal 4
0: DP DataExchange (default)
2: disabled (Multi-Config mode)

8,9

Assignment for terminal 5
0: DP DataExchange (default)
2: disabled (Multi-Config mode)

10,11

Assignment for terminal 6
0: DP DataExchange (default)
2: disabled (Multi-Config mode)

12,13

Assignment for terminal 7
0: DP DataExchange (default)
2: disabled (Multi-Config mode)

0

14,15

Assignment for terminal 8
0: DP DataExchange (default)
2: disabled (Multi-Config mode)

...

...

...

31

14,15

Assignment for terminal 128
0: DP DataExchange (default)
2: disabled (Multi-Config mode)

Note

It can happen under multi-configuration mode that the CfgData exceeds 64 bytes. In such a
case, the CfgData must be enlarged.