BECKHOFF BK3xx0 User Manual

Page 30

background image

Notes on the Documentation

28

Fieldbus Components

Byte Bit Value Description

GSD file

0

bin

WORD alignment inactive (default)

9

5

1

bin

WORD alignment active (see WORD alignment)

Extended

0

bin

K-Bus mode is synchronous (see K-Bus cycle)

9

6

1

bin

K-Bus mode FreeRun (default)

Standard

00

bin

Reaction to PROFIBUS error: K-Bus cycle is abandoned (default, digital
outputs become 0, complex outputs are set to a configured substitute value)
(see Reaction to PROFIBUS errors)

01

bin

Reaction to PROFIBUS error: K-Bus outputs become 0

10

0-
1

10

bin

Reaction to PROFIBUS error: K-Bus outputs remain unchanged

Standard

00

bin

Reaction to K-Bus error: DP data exchange is abandoned (default) (see K-
Bus interruption)

01

bin

Reaction to K-Bus error: DP inputs set to 0

10

2-
3

10

bin

Reaction to K-Bus error: DP inputs remain unchanged

Standard

11

3-
6

X

Maximum length of the diagnostic data. Allowed values: 16, 24, 32, 40, 48,
56, 64 (see Terminal diagnosis)

Extended

0

bin

If K-Bus mode is synchronous: standard synchronous mode (default) (see K-
Bus cycle)

01

bin

If K-Bus mode is synchronous: synchronous mode with optimised input
update (one cycle)

12

0-
1

10

bin

If K-Bus mode is synchronous: synchronous mode with optimised input
update (two cycles)

Extended

12

4-
7

0

bin

Maximum DP buffer lengths not changed

Extended

12

4-
7

15

The maximum DP buffer lengths are changed using the values from
UserPrmData 37-40 (see Multi-configuration mode)

Extended

13

0-
7

X

Delay time (in µs) high byte (see K-Bus cycle)

Extended

14

0-
7

X

Delay time (in µs) low byte (see K-Bus cycle)

Extended

15-
30

0-
7

X

Assignment of Bus Terminals 1 to 64 (see Multi-configuration mode)

Extended

31-
36

0-
7

-

reserved

Extended

37

0-
7

X

Maximum length of the input data (see Multi-configuration mode)

Extended

38

0-
7

X

Maximum length of the output data (see Multi-configuration mode)

Extended

39

0-
7

X

Maximum length of the diagnostic data (see Multi-configuration mode)

Extended

40

0-
7

X

Maximum length of the configuration data (see Multi-configuration mode)

Extended

41-
56

0-
7

X

Assignment of terminals 65 to 128 (see Multi-configuration mode)

Extended