beautypg.com

6 operational failures, 1 error messages, 1 error messaging – Avery Dennison ALS 104 User Manual

Page 43: 2 list of error messages, 6 operational, Failures, 6 . 1 e r r o r m e s s a g e s, Als 104 gb, Perational, Rror

background image

39

6

O

PERATIONAL

FAILURES

6.1 E

RROR

MESSAGES

ALS

104

GB

6.1.1

Error messaging

Error messages are displayed as follows:

xxxxxxxxxxxxxxxx = Message text

At the same time, a signal is activated at the signal
output of the unit, which can be used to switch on an
external visual or audible signal.

£

Press the key

to reset the error message.

Before considering applying any remedies, check
whether the message appears repeatedly:

£

Turn off the unit and switch it on again after 10
seconds.

– It is important to wait at least 10 seconds before

switching the unit back on again.

6.1.2

List of error messages

[50]

Overview of numbered error messages.

xxxxxxxxxxxxxxxx
Reset Alarm?

No.

Message text

Possible cause

Remedy

1

General Alarm

– Motor failure
– Motherboard malfunction

£

Request a service technician

3

Missing Label

– Max. number of missing label was

exceeded

£

Check the label material

4

Material Low

Without a connected roll diameter check:
– The product sensor may have been

mistakenly connected to the socket for
the roll diameter check.

– Internal sensor connection cables may

be mixed up.

With a connected roll diameter check:
– The material roll has fallen short of the

critical diameter.

£

Connect the product sensor to the
correct socket.

£

Request a service technician.

£

Prepare to change the material roll.

5

Unknown Length The function

LABEL SETUP > Label Size

was

cancelled unsuccessfully.
– No label material inserted.
– Electronic fault.

£

Insert label material.

£

Request a service technician.

6

O

P E R A T I O N A L

F A I L U R E S

6.1