14
2
P
RODUCT
DESCRIPTION
2.1 O
VERVIEW
ALS
104
GB
3) Selectable by jumper setting
Internal Interfaces
Status messages, test functions
Dimensions
4) Measurements without the dispensing plate bracket and dispensing plate
Environmental conditions
Integration
Certificates
– CE, TÜV/GS, FCC, CCC, GOST, NRTL, US/CA
– The regulation DIN EN 55022 requires for class A
devices the following text to be printed in the
manual:
„WARNING: This is a class A product. In a domestic
environment this product may cause radio
interference in which case the user may be required
to take adequate measures.“
– The FCC regulation requires the following
information text for class A products:
„NOTE: This equipment has been tested and found
to comply with the limits for a Class A digital device,
pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection
against harmful interference when the equipment is
operated in a commercial environment. This
equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in
accordance with the instruction manual, may cause
harmful interference to radio communications.
Operation of this equipment in a residential area is
likely to cause harmful interference in which case
the user will be required to correct the interference
at his own expense“
PLC outputs:
(connection with D-Sub
15 connector, optional
with 8-pin M12)
3x PNP, 24 V, max.
500 mA/channel, total
permissible output cur-
rent: 1500 mA
One insulated relay out-
put, max. 125 mA (NC/
NO), functions parallel to
the PNP outputs (selec-
table)
Optional output via an
8-pin M12 connector
UART for RFID
none
Connector for add motor
driver boards
none
Thermal print head
connectors
none
Automatic halt, if
... the label roll is spent or
no gap was found.
… the maximum allowab-
le number of missing la-
bels has been exceeded.
Test functions:
Automatic diagnostics
check when switched on
Height x width x depth:
4)
492 x 488 x 353 mm
Weight:
33 kg
Operating temperature:
5 to 40°C
Humidity:
30 to 85%, (non-conden-
sing)
Noise level (at a distance
of 1 m):
70 dB(A)
Protection class:
IP 41
IP 65 optional (with ex-
tras)
Mounting points:
side / bottom / rear
Labelling positions:
top / side / bottom
Dispensing edges:
V-shape
L-shape; fixture 90° pivo-
ting, for all L-shape types
(4“ L-shape disp. edge:
material width up to
100 mm only)