5 after operation, 1 maintenance and cleaning, 1 changing fuses – Avery Dennison ALS 104 User Manual
Page 41: 5 after, Operation, 5 . 1 m a i n t e n a n c e a n d c l e a n i n g, Als 104 gb, Fter, Aintenance, Cleaning

37
5
A
FTER
OPERATION
5.1 M
AINTENANCE
AND
CLEANING
ALS
104
GB
5.1.1
Changing fuses
WARNING!
The machine operates using mains voltage!
Touching live electrical parts may expose
you to hazardous electrical currents and
may lead to burns.
£
Make sure that the machine is switched
off and the power cable is unplugged
before removing the fuse insert.
CAUTION!
Risk of fire, if a wrong fuse type is inserted.
£
Only replace fuses with the type and
rating specified in this manual.
ALS 104 with dust/splash guard: Fuses may
only be replaced by qualified service techni-
cians.
£
Turn off the unit. Unplug the power cable.
£
Remove the fuse insert. To do this, press the latch
upwards [47A] and pull out the insert [48A].
– The fuse insert is located directly above the On/Off
switch.
£
Take the fuses out of the fuse insert.
£
Replace defective fuses.
Required fuse type:
– 2x F5AH / 250 V
– The same fuse type is required for 230 V as
for 115 V.
– The fuses must conform to IEC 60127-2/5
(for example, “Wickmann 181 Series”)
[47] Unlock the fuse insert.
[48] Remove the fuse insert (A).
A
A
[49] Remove (A) fuses.
A
5
A
F T E R
O P E R A T I O N
5.1
MAINTENANCE AND CLEANING