Dispensing speed

The dispensing speed can be set to a fixed value or can
be configured to automatically adjust to the speed of
the conveyor belt (speed adaption). The second
possibility requires a speed sensor to be connected; it
measures and relays the conveyor speed to the
dispenser.

Configuring a fixed value:

£

Set the speed in dispensing mode with the two left
keys (see “Dispensing mode” on page 19).

Configuring speed adaption:

£

Turn the function on by setting

MACHINE SETUP >

Speed Adaption

to ‘On’.

£

MACHINE SETUP > Encoder Resol.

and

MACHINE SETUP > Encoder Diameter

set as

appropriate for the employed speed sensor.

– See the service manual for information on

suitable speed sensors.