3 operating modes, 1 dispensing mode, Dispensing speed – Avery Dennison ALS 104 User Manual
Page 23: Start offset, Dispensing manually, 2 . 3 o p e r a t i n g m o d e s, Dispensing speed start offset dispensing manually, Als 104 gb

19
2.3 O
PERATING
MODES
ALS
104
GB
2.3.1
Dispensing mode
– This is the operating mode of the unit when switched
on.
– The display shows the dispensing speed [21A] and
the start offset [21C].
– In dispensing mode, the button assignments are as
shown on the buttons.
– Both settings can be increased (‘+’ button) or
lowered
(‘–’-button) during dispensing operation [21].
– For more information on adjusting the dispensing
operation, see “Function menu settings” on page 33
Dispensing speed
– Setting range:
fix: [5.0…30.0] m/min
var: [0.0…30.0] m/min
– Display fix: The dispensing speed is constant.
– Display var: The dispensing speed adjusts to the
speed of the conveyor belt (‘speed adaption’).
Start offset
– Setting range: [0.0…999.9] mm
– The start offset indicates the distance between the
product sensor and the dispensing edge.
Dispensing manually
To manually trigger the dispensing of individual labels:
£
Press the button
.
– Dispensing speed: As specified in the setting (see
above).
[21] Control panel and button functions in dispensing mode.
A Dispensing speed display (here: 12.2 m/min)
B Dispense label button
C Start offset display (here: 0 mm)
D Button to lower dispensing speed
E Button to increase dispensing speed
F Button to lower start offset
G Button to increase start offset
Speed
12.2 fix
Offset
0.0
+
+
–
–
ON
STATUS
A
C
D
E
F
G
B
2.3