Defining the code 93 options tag (optional), Defining the code 128 options tag (optional) – Avery Dennison Pathfinder 6057 LNT Programmer Manual using XML User Manual
Page 44
4-4 LNT Programmer’s Manual
D e f i n i n g t h e Co d e 9 3 O p t i o n s T a g ( O p t i o n al )
Use the Options tag to define Code 93-specific information.
Valid values include: a 32-bit unsigned decimal number.
It contains the following attributes: density and narrowbar.
Syntax
density
Bar code density. Options: 3, 4, 5, 7, and 10 as shown belo w. The default is
7
Density
Selector
Density
(% or cpi)
Narrow Element Width
in Dots/Mils
3
3.7
6 / 29.6
4
4.5
5 / 24.6
5
5.6
4 / 19.7
7
7.5
3 / 14.8
10
11.2
2 / 9.9
narrowbar
Use the density table abo ve. Using a non-standard value may produce
unreadable bar codes. Define in Pi xels.
Example
Creates a Code 93 bar code with a density of 5 and does not specify a narrow bar value.
D e f i n i n g t h e Co d e 1 2 8 O p t i o n s T ag ( O p t i o n al )
Use the Options tag to define Code 128-specific information.
Valid values include: a 32-bit unsigned decimal number.
It contains the following attributes: density and narrowbar.
Syntax
density
Bar code density. Options: 4, 6, 8, and 20 as shown belo w. The default is 8.
Density
Selector
Density
(% or cpi)
Narrow Element Width
in Dots/mils
20
3.5/7.0
5/24.6
4
4.4/8.7
4/19.7
6
5.8/11.7
3/14.8
8
8.7/17.5
2/9.9
narrowbar
Use the density table abo ve. Using a non-standard value may produce
unreadable bar codes. Define in Pi xels.
Example
Creates a Code 128 bar code with a density of 6 and does not specify a narrow bar value.