3.1.116 testWatchdogTimer

Name

testWatchdogTimer—tests the watchdog timer device. The test application checks for timer
accuracy allowing a tolerance of 30 microseconds. Both interrupt and reset modes are
validated through this test.

Synopsis

testWatchdogTimer -d [-r] [-t] [-v]

Parameters

-d Ps: Device Name

-r 0 : Set to Reset Mode (Default = Interrupt Mode)

-t Pd: Time in Milliseconds to Run Test (Default = 5000)

-v 0 : Enable Verbose Mode

Example

The following example indicates a typical display when using the testWatchdogTimer
command.

MOTLoad> testWatchdogTimer -d/dev/wdt0 -t1000 -v