102 testramquick, 102testramquick, Testramquick – Artesyn MOTLoad Firmware Package User's Manual (February 2015) User Manual
Page 190: Motload commands

MOTLoad Commands
MOTLoad Firmware Package User’s Manual (6806800C24D)
190
3.1.102 testRamQuick
Name
testRamQuick—performs a test which verifies that the memory test block can be written to
and read from using data patterns. Each pass of this test fills the test block with a data pattern
by writing the current data pattern to each memory location from a local variable and reading
it back into that same register. The local variable is verified to be unchanged only after the write
pass through the test range. This test uses a first pass data pattern of 0x00000000 and
0xFFFFFFFF for the second pass.
Note: testRamQuick only test memory in blocks, thus specifying a memory area size that is
not a multiple of the block size results in part of the memory area being untested.
Synopsis
testRamQuick [-a] [-b] [-i] [-n] [-t] [-v]
Parameters
-a Ph: Address to Start (Default = Dynamic Allocation)
-b Ph: Block Size (Default = 16 KB)
-i Pd: Iterations (Default = 1)
-n Ph: Number of Bytes (Default = 1 MB)
-t Pd: Time Delay Between Blocks in OS Ticks (Default = 1)
-v 0: Verbose Output
Example
The following example indicates a typical display when using the testRamQuick command.
MOTLoad> testRamQuick -v
Executing RAM Quick: PASSED
See Also
,