AMETEK SLM Series Rev B User Manual
Page 70
![background image](https://www.manualsdir.com/files/771726/content/doc070.png)
GPIB/RS-232 Programming Operation
SLM-Series AC/DC Electronic Load
4-28
M540072-01 Rev B
NG
Purpose:
To read the set value of NG.
Command Syntax:
All Modules:
NG?{;|NL}
Description:
NG? Reads back the condition indicating light of NG. “0” denotes that NG (NO GOOD)
indicating light has been extinguished. “1” denotes that NG indicating light has been lit.
NG Enable /Disable
Purpose:
To read NG ON/OFF setting.
Command Syntax:
SLD Modules:
NGAB{?}{;|NL}
Description:
NGAB? returns the presently NG ON/OFF status, “0” indicates NG disable, and “1” indicates
NG enable.
PERIOD
Purpose:
The dynamic mode's Tlow or Thigh duration query command
Command Syntax:
SLM DC, SLD Modules: PERI:{LOW|HIGH}?{NL}
Description:
PERI:LOW? returns the presently programmed low duration time in dynamic load mode
PERI:HIGH? returns the presently programmed high duration time in dynamic load mode
The engineering unit is “msec”.
RISE Time
Purpose:
The dynamic load mode's RISE slew rate query command
Command Syntax:
SLM DC Modules:
RISE?{NL}
Description:
RISE? returns the presently programmed low load current level in Constant Current mode
The engineering unit is “A/us”.
FALL Time
Purpose:
The dynamic load mode's FALL slew rate query command.
Command Syntax:
SLM DC Modules:
FALL?{NL}
Description:
FALL? returns the presently programmed low load current level in Constant Current mode
The engineering unit is “A/us”.