Operation

SLM-Series AC/DC Electronic Load

3-16

M540072-01 Rev B

3.5.4 Over

Temperature Protection (OTP)

SLM-Series AC/DC Electronic load is provided with a temperature sensor. Over
temperature protection (OTP) is tripped when the heat dissipater temperature
exceeds about 85ºC ±5ºC, and the lower DM flashes “oTP”. Once the over
temperature condition is reset, the lower DM resumes normal display.

When OTP occurs, check the ambient working temperature and ventilation. The air
outlet on requires a distance of greater than 6 in / 15 cm from any obstruction, for
proper ventilation.

Model

OVP

OCP

OPP

SLH-500-4-1200

525.0 V

4.20 A

1260 VA

SLH-500-6-1800

525.0 V

6.30 A

1890 VA

SLH-300-12-1200

315.0 V

12.60 A

1260 VA

SLH-300-12-1800

315.0 V

12.60 A

1890 VA

SLH-300-18-1800

315.0 V

18.90 A

1890 VA

Table 3-5 SLH AC-series Protection Setting Values