4 specifications, 5 regulatory compliance – AMETEK SLM Series Rev B User Manual
Page 22

Features, Functions, Specifications
SLM-Series AC/DC Load
1-6
M540072-01 Rev B
1.4 SPECIFICATIONS
NOTE: The following specifications apply 25°±5°:
MODEL
SLM-60-20-300
SLM-150-8-300
SLM-300-4-300
SLM-500-1-300
INPUT RATINGS
Power (VA)
300 VA
300 VA
300 VA
300 VA
Current(Ampere)
20 Arms
8 Arms
4 Arms
1 Arms
Voltage(Volt)
60 Vrms
150 Vrms
300 Vrms
500Vdc/300 Vrms
Frequency
DC, 40 - 70Hz (CC Mode) ; DC - 70Hz (CR Mode)
CC MODE
Range
0-10 / 10-20 A
0-4 / 4-8 A
0-2 / 2-4 A
0-0.5 / 0.5-1 A
Resolution
2.5 / 5 mA
1 / 2 mA
0.5 / 1 mA
0.125 / 0.25 mA
Accuracy
±0.5% of (setting + range)
Low current
0 - 1 A
0 - 0.4 A
0 - 0.2 A
0 - 0.05 A
Accuracy
± 2% of (setting + range)
CR MODE
Range II/I 0.3-1.2 / 1.2-4.8K 1.875-7.5 / 7.5-30K
7.5-30 / 30-120K
50-200 / 200-800K
Resolution
0.83 / 0.2083 mS
0.13 / 0.033 mS
0.033 /0.0083 mS 0.005 / 0.00125 mS
Accuracy
±0.5% of (setting + range)
4 1/2 DVM
Range
60 V
150 V
300 V
500 V
Resolution
0.01 V
0.01 V
0.1 V
0.1 V
Accuracy
±(0.5% of reading + 0.2% of range)
4 1/2 DAM
Range
20 A
8 A
4 A
1 A
Resolution
0.01 A
0.001 A
0.001 A
0.001 A
Accuracy
±(0.5% of reading + 2% of range) ; ±0.5% of (reading + range) @ 50/60Hz
4 1/2 WATT METER
Range
300 W
Resolution
0.1 W
Accuracy
± (0.5% of reading)± 3W
VA METER
Vrms×Arms
Imonitor
5 A/V
2 A/V
1 A/V
0.2 A/V
PROTECTION
OPP
~315 VA
~315 VA
~315 VA
~315 VA
OCP
~21 A
~8.4 A
~4.2 A
~1.05 A
OVP
~63 V
~175.5 V
~315 V
~525 V
OTP
85℃
85℃
85℃
85℃
Table 1-1 SLM-Series AC/DCSpecifications
1.5 REGULATORY
COMPLIANCE
•
Certified to UL 61010-1, CSA C22.2 No. 61010.1 and IEC/EN 61010-1
•
CE Compliant:
o
Low Voltage Directive (73/23/EEC) using EN 61010-1
o
EMC Directive (89/336/EEC) using EN 61326
•
FCC Compliant to 21 CFR, Subpart J