1.4 SPECIFICATIONS

NOTE: The following specifications apply 25°±5°:

MODEL

SLM-60-20-300

SLM-150-8-300

SLM-300-4-300

SLM-500-1-300

INPUT RATINGS

Power (VA)

300 VA

300 VA

300 VA

300 VA

Current(Ampere)

20 Arms

8 Arms

4 Arms

1 Arms

Voltage(Volt)

60 Vrms

150 Vrms

300 Vrms

500Vdc/300 Vrms

Frequency

DC, 40 - 70Hz (CC Mode) ; DC - 70Hz (CR Mode)

CC MODE

Range

0-10 / 10-20 A

0-4 / 4-8 A

0-2 / 2-4 A

0-0.5 / 0.5-1 A

Resolution

2.5 / 5 mA

1 / 2 mA

0.5 / 1 mA

0.125 / 0.25 mA

Accuracy

±0.5% of (setting + range)

Low current

0 - 1 A

0 - 0.4 A

0 - 0.2 A

0 - 0.05 A

Accuracy

± 2% of (setting + range)

CR MODE

Range II/I 0.3-1.2 / 1.2-4.8K 1.875-7.5 / 7.5-30K

7.5-30 / 30-120K

50-200 / 200-800K

Resolution

0.83 / 0.2083 mS

0.13 / 0.033 mS

0.033 /0.0083 mS 0.005 / 0.00125 mS

Accuracy

±0.5% of (setting + range)

4 1/2 DVM

Range

60 V

150 V

300 V

500 V

Resolution

0.01 V

0.01 V

0.1 V

0.1 V

Accuracy

±(0.5% of reading + 0.2% of range)

4 1/2 DAM

Range

20 A

8 A

4 A

1 A

Resolution

0.01 A

0.001 A

0.001 A

0.001 A

Accuracy

±(0.5% of reading + 2% of range) ; ±0.5% of (reading + range) @ 50/60Hz

4 1/2 WATT METER

Range

300 W

Resolution

0.1 W

Accuracy

± (0.5% of reading)± 3W

VA METER

Vrms×Arms

Imonitor

5 A/V

2 A/V

1 A/V

0.2 A/V

PROTECTION

OPP

~315 VA

~315 VA

~315 VA

~315 VA

OCP

~21 A

~8.4 A

~4.2 A

~1.05 A

OVP

~63 V

~175.5 V

~315 V

~525 V

OTP

85℃

85℃

85℃

85℃

Table 1-1 SLM-Series AC/DCSpecifications

1.5 REGULATORY

COMPLIANCE

Certified to UL 61010-1, CSA C22.2 No. 61010.1 and IEC/EN 61010-1

CE Compliant:

o

Low Voltage Directive (73/23/EEC) using EN 61010-1

o

EMC Directive (89/336/EEC) using EN 61326

FCC Compliant to 21 CFR, Subpart J