beautypg.com

AMETEK SLM Series Rev B User Manual

Page 69

background image

SLM-Series AC/DC Electronic Load

GPIB/RS-232 Programming Operation

M540072-01 Rev B

4-27

FREQUENCY

Purpose:
To read the set frequency of FREQ.
Command Syntax:
SLM AC Modules:

FREQ?{;|NL}

Description:
Reads back the set frequency of FREQ, unit is Hz.

VOLTAGE Limit

Purpose:
To read the set value of upper/lower limit value of threshold voltage.
Command Syntax:
All Modules:

LIM:VOLT:{HIGH/LOW}?{;|NL}

Description:
LIM:VOLT:LOW? Reads back the lower limit set value of threshold voltag;, unit is “volts" (V).

CURRENT Limit

Purpose:
To read the set value of upper/lower limit value of threshold current.
Command Syntax:
All Modules:

LIM:CURR{HIGH|LOW}?{;|NL}

Description:
LIM:CURR:LOW? Reads back the lower limit set value of threshold current; unit is
“amps (A)”.

POWER Limit

Purpose:
To read the set value of upper/lower limit value of threshold power(W).
Command Syntax:
SLM DC Modules:

LIM:POW{HIGH|LOW}?{;|NL}

Description:
LIM:POW:LOW? Reads back the lower limit set value of threshold power; unit is “watts” (W).

VA Limit

Purpose:
To read the set value of upper/lower limit value of threshold power (VA).
Command Syntax:
SLM AC Modules:

LIM:VA{HIGH|LOW}?{;|NL}

Description:
LIM:VA:LOW? Reads back the lower limit set value of threshold power, unit is (VA).