beautypg.com

AMETEK SLH Series RevB User Manual

Page 58

background image

GPIB/RS232 Programming Operation

SLH-Series AC High Power Electronic Load

4-16

M540073-01 Rev C

POWER METER

Purpose:
To read the value of Watt meter.
Command Syntax:
MEAS:POW?{;|NL}
Description:
MEAS:POW? Reads back the value of 4 digit of the Watt meter; unit is (W).

VA METER

Purpose:
To read the value of VA meter.
Command Syntax:
MEAS:VA?{;|NL}
Description:
MEAS:VA? Reads back the value of 4 digit of VAmeter, unit is (VA).

SYNCHRONOUS ON/OFF

Purpose:
To read the setting condition of SYNC.
Command Syntax:
SYNC?{;|NL}
Description:
SYNC? Read back the condition of SYNC. “0” denotes OFF, “1” denotes ON.

SENSE ON/OFF

Purpose:
To read the setting condition of Sense ON or OFF.
Command Syntax:
SENS?{;|NL}
Description:
SENS? Reads back the setting condition of SENS. “0” denotes OFF, “1” denotes ON.

WATT Meter ON/OFF

Purpose:
To read the setting condition of WATT.
Command Syntax:
WATT?{;|NL}
Description:
WATT? Reads back the setting condition of WATT. “0” denotes OFF, “1” denotes ON.