AMETEK SLH Series RevB User Manual
Page 55

SLH-Series AC High Power Electronic Load
GPIB/RS232 Programming Operation
M540073-01 Rev C
4-13
RESISTANCE Level
Purpose:
The Constant Resistance mode's load resistance level query command.
Command Syntax:
CR:{HIGH|LOW}{?}{;|NL}
Description:
RES:LOW? returns the presently programmed low load resistance level in Constant
Resistance mode the electronic load.
The engineering unit is “OHM”.
LOAD ON/OFF
Purpose:
LOAD ON or LOAD OFF status query command.
Command Syntax:
LOAD?{NL}
Description:
LOAD? returns the present load status, “0” indicates LOAD OFF, and “1” indicates LOAD
ON.
LEVEL HIGH/LOW
Purpose:
Static mode's LEVEL low or high status query command or active LEVEL of AC electronic
load query command.
Command Syntax:
LEVE?{NL}
Description:
LEVE? returns the present level status, “0” indicates LEVEl LOW, and “1” indicates LEVEl
HIGH.
PRESET ON/OFF
Purpose:
PRESet ON or OFF status query command.
Command Syntax:
All Modules:
PRES?{NL}
Description:
PRES? returns the present preset status, “0” indicates PRESet OFF, and “1” indicates
PRESet ON.
MODE
Purpose:
CC or CR operating mode query command.
Command Syntax:
MODE?{NL}
Description:
MODE? returns the present operating mode status, ”0” indicates CC MODE, ”1” indicates
CR MODE.