M540073-01 Rev C
4-1
SECTION 4
GPIB/RS-232 PROGRAMMING
OPERATION
4.1 INTRODUCTION
The rear panel of SLH-series is designed for automated and/or remote testing from a
computer through a GPIB or RS-232 interface. This feature can be used as an
automatic load/cross load regulation and centering voltage testing for a switching
power supply or a rechargeable battery charge/discharge characteristic testing.
4.2 SLH-SERIES GPIB COMMAND LIST
4.2.1 Setting
Commands
Function Command Format
SET AUTO FREQUENCY
DETECT ON/OFF
AFREQ{SP}{0|1|OFF|ON}{;|NL}
SET SYNC ON/OFF
SYNC{SP}{0|1|OFF|ON}{;|NL}
SET SENC ON/OFF
SENS{SP}{0|1|OFF|ON}{;|NL}
SET WATT ON/OFF
WATT{SP}{0|1|OFF|ON}{;|NL}
SET BANK
BANK{SP}{d}{;|NL}
d:0 ~ 10
SET WAVE
WAVE{SP}{m}{;|NL}}
m:1 ~ 5
SET FREQUENCY
PREQ{SP}{NR2}{;|NL}
NR2:###.#####
SET VOLTAGE LOW LIMIT
VL{SP}{NR2}{;|NL}
SET VOLTAGE HIGH LIMIT
VH{SP}{NR2}{;|NL}
SET CURRENT LOW LIMIT
IL{SP}{NR2}{;|NL}
SET CURRENT HIGH LIMIT
IH{SP}{NR2}{;|NL}
SET WATT LOW LIMIT
WL{SP}{NR2}{;|NL}
SET WATT HIGH LIMIT
WH{SP}{NR2}{;|NL}
SET VA LOW LIMIT
VAL{SP}{NR2}{;|NL}
SET VA HIGH LIMIT
VAH{SP}{NR2}{;|NL}
SET CURRENT
CURR:{LOW|HIGH|A|B}{SP}{NR2}{;|NL} NR2:###.#####
SET RESISTANCE
RES:{LOW|HIGH|A|B}{SP}{NR2}{;|NL}
SET LOAD ON/OFF
LOAD{SP}{0|1|OFF|ON}{;|NL}
SET LEVEL LOW/HIGH
LEV{SP}{0|1|LOW|HIGH}{;|NL}
SET PRESENT ON/OFF
PRES{SP}{0|1|OFF|ON}{;|NL}
SET MODE
MODE{SP}{0|1|2|CC|CR|CV}{;|NL}
SET CLEAR STATE
CLER{;|NL}
SET STORE STATE
STORE{SP}{m}{;|NL}
m:1 ~ 5
SET RECALL STATE
RECALL{SP}{m}{;|NL}
m:1 ~ 5
Table 4-1 GPIB Setting Command Summary