AMETEK SLH Series RevB User Manual
Page 56
GPIB/RS232 Programming Operation
SLH-Series AC High Power Electronic Load
4-14
M540073-01 Rev C
NAME
Purpose:
Electronic Load module model number query command.
Command Syntax:
All Modules:
NAME?{NL}
Description:
NAME? return the active Electronic Load model number, 325x for SLH AC-series loads.
PROTECTION Status Register
Purpose:
OPP, OTP, OVP, and OCP protection status query command.
Command Syntax:
All Modules:
PROT?{NL}
Description:
PROT? returns the present protection status; the status byte register summarizes all of the
protection status events from all status register. the following figure describes the status
byte the happened on the SLH-series Electronic load. The PROT status byte register is
cleared when a CLER command clears all of the PROT and ERR status registers.
bit 7
bit 0
7
6
5
4
3
2
1
0
OPP
OTP
OVP
OCP
Figure 4-1 Protection Status Register
Purpose:
ERRor status register query command.
Command Syntax:
All Modules:
ERR?{;|NL}
Description:
ERR? returns the present error status; the status byte register summarizes all of the error
status events from all status registers. the following figure describes the status byte the
happened on the SLH-series electronic load. The ERR status byte register is cleared when
a CLER command clears all of the PROT and ERR status registers.
bit 7
bit 0
7
6
5
4
3
2
1
0
Limited
Range Changed
Invalid Command
Invalid Operating
Figure 4-2 Error Status Byte Register