2.6.1 -HV Option Specifications

The -HV option provides an AC only output range of 0 to 400 Vac L-N. Specifications unique to
the -HV option are shown in the table below.

Output Parameter

RS90

RS180

RS270

RS360

RS450

RS540

Modes

Pi Controller

AC

Voltage:

Ranges (L-N):

0 -400 V

Resolution:

0.1 V

Accuracy:

± 0.25% of Full Scale / ± 1.0 Vac rms

Output Coupling

AC coupled

Power (total power for all phases, either range, at full scale voltage)

AC Mode

90 KVA

180 KVA

270 KVA

360 KVA

450 KVA

540 KVA

Current

Note: Current, maximum amps per phase available between 50 and 100 % of voltage range.

75 A

150 A

225 A

300 A

375 A

450 A

Peak Current

AC Mode

225 A

450 A

675 A

900 A

1125 A

1350 A

Frequency:

Range:

45 Hz – 819 Hz
with –LF option: 45 Hz – 500 Hz
with –HF option: 45 Hz – 905 Hz (see also –HF option specification.)