FREQ TRANSIENTS

The above test can be selected by scrolling to the highlighted selection using the up and down
key and the ENTER key to start the selected test.

VOLT MAX

Standard/Group

RTCA

Group1

Group2

Group3

Voltage

1

97

97

104

97

97

3

98.5

98.5

105.5

98.5

98.5

Frequency

400

400

370

360

360

Table 9-10: Abnormal Voltage Minimum

Standard/Group

RTCA

Group1

Group2

Group3

Voltage

1

134

134

122

134

134

3

120.5

132.5

120.5

132.5

132.5

Frequency

400

400

430

650

800

Table 9-11: Abnormal Voltage Maximum

This test will set the voltage and frequency to levels defined by Figure 9-10 for 5 minutes. The
test will be repeated for Group1 only as indicated in Table 9-10 for voltage and Table 9-11 for
frequency. All Groups will repeat the test using Table 9-10 for the voltage setting and Table 9-
10 or Table 9-11for the frequency setting. The

key (backspace) will terminate the test at any

time.

VOLT MIN

This test will set the voltage and frequency to levels defined by Table 9-11 for 5 minutes. The test
will be repeated for Group1 only as indicated in Table 9-11. All Groups will repeat the test using
Table 9-11 for the voltage setting and Table 9-10 for the frequency setting. The

key

(backspace) will terminate the test at any time.

VOLT UNDER

This test will drop the output voltage from 115 volts to 60 volts for 7 seconds.

VOLT SURGE

This test requires 180 volt output voltage. If the power source is set at the low voltage range,
the high voltage range will be selected before the test starts. At the end of the test the AC
source will be switched back to the low range.

The output voltage will surge to 180 volts for 100 ms. followed by drop to 148 volts for 1 sec
before it returns to 115 volts. The

key (backspace) will terminate the test at any time.

FREQUENCY TRANSIENTS (Group 1 only)

Seq. No.

Frequency

Time

1

400

5 minutes

2

480

5 sec.

3

400

10 sec.

4

320

5 sec.

5

400

10 sec.

Table 9-12: Abnormal Frequency Transient

This test will set the voltage at 115V and will remain at this voltage through out the test. The
test will cycle the frequency three times as shown in Table 9-12. Each repeat will start from
sequence 2.