2.3 Environmental
Parameter
Specification
Operating Temp:
0° to +35
°
C. (Except in CP mode).
+32° to +104° F.
Storage Temp:
-40° to +85
°
C.
-40° to +185° F.
Altitude:
< 2000 meters
Relative Humidity:
0-95 % RAH, non-condensing maximum for temperatures up to 31
°
C
decreasing linearly to 50% at 40
°
C.
Installation/Over voltage
Category:
ΙΙ
Pollution Degree:
2
Indoor Use Only
Vibration:
Designed to meet NSTA 1A transportation levels.
Shock:
Designed to meet NSTA 1A transportation levels.
2.4 Regulatory
Electromagnetic
Emissions and Immunity:
Designed to meet EN50081-2 and EN50082-2 European Emissions and
Immunity standards as required for the “CE” mark.
Acoustic Noise:
TBD 75 dBA maximum at 0% to 50% load, 80 dBA maximum greater than 50%
load to 100% load. Measured at one meter.
Safety:
Designed to EN 61010-1 European safety standards as required for the “CE”
mark.
2.5 Front Panel Controls
Controls:
Shuttle knob:
Allows continuous change of all values including output calibration and range
change.
Decimal keypad:
A conventional decimal keypad facilitates quick entry of numerical values such
as voltage, current limit, etc. The large blue enter key will make the value you
enter effective. Using the SET key allows the user to preset all parameter
values and update them all at once by pressing the Enter key.
Up/down arrow keys:
A set of up and down arrow keys is used to move the cursor position in all
menus. This allows quick selection of the desired function or parameter.
Function keys:
Measure key will display most measurement values. Program key will show all
program parameters. Output on/off key for output relay control. Phase key will
switch display to show program and measured values for each phase.