2 mechanical – AMETEK RS Series User Manual
Page 20
User Manual
AMETEK Programmable Power
RS Series
20
2.1.7 Unit Protection
Input Over current:
In-line fast acting fuses. Check fuse rating in Service and Maintenance section.
Ratings will depend on AC input configuration settings.
Circuit breaker for LV supply.
Input Over voltage:
Automatic shutdown.
Input Over voltage
Transients:
Surge protection to withstand EN50082-1 (IEC 801-4, 5) levels.
Output Over current:
Adjustable level constant current mode with programmable set point.
Output Short Circuit:
Peak and RMS current limit.
Over temperature:
Automatic shutdown.
2.2 Mechanical
Parameter
Specification
Dimensions:
(for each RS chassis)
Height:
74.5”
1892.3 mm
Width:
30.3”
769.6 mm
Depth:
38.3”
972.8 mm
Unit Weight:
(for each RS chassis)
Net:
2150 lbs / 975 Kg approximately
2475 lbs / 1123 Kg approximately including –AV option
Shipping:
2450 lbs / 1111 Kg
approximately
2775 lbs / 1258 Kg approximately including –AV option
Material:
Steel chassis with aluminum panels and covers.
Finish:
Light textured painted external surfaces.
Panels semi-gloss polyurethane color no. 26440 (medium gray)
Cooling:
Fan cooled with air intake on the front and exhaust to the rear.
Fans:
14 x 225CFM.
Air displacement
50 Cu Ft/sec. Max.
Internal Construction:
Modular sub assemblies.
Rear Panel
Connections:
(See section 3 for description of connections)
•
Cable entry and strain relieve for AC input wiring
•
Cable entry and strain relieve for output wiring
•
External sense terminal block (Remote voltage sense)
•
System interface (2x)
•
Clock and Lock BNC's (requires -LKM or -LKS options)
•
RS232, USB, GPIB, LAN (option)
•
Trigger In BNC
•
Trigger Out BNC
•
Function Strobe BNC
•
Output Status