Page 170

background image

User Manual

AMETEK Programmable Power

RS Series

170

7. Voltage Surge (Overvoltage) test

8. Frequency Transients test(Group 1 only)

Frequency Variation test (Group 2 and 3 only)

DC Source:

1. Normal State Voltage test

2. Momentary Power Interrupt (Undervoltage) test

3. Voltage Surge and Under

9.3.1.3.2 EMERGENCY TEST

AC Source:

1. Emergency Voltage and Frequency minimum

2. Emergency Voltage and Frequency maximum

3. Voltage unbalance

DC Source:
1. Emergency Voltage

9.3.1.3.3 ABNORMAL TEST

AC Source:

1. Abnormal Voltage minimum

2. Abnormal Voltage maximum

3. Voltage Drop

4. Voltage Surge

5. Frequency Transients test (group 1 only)

DC Source:

1. Abnormal Voltage minimum

2. Abnormal Voltage maximum

3. Abnormal Voltage low
4. Voltage Drop

5. Voltage Surge

9.3.1.4 Front Panel Entry

To perform a test from the keyboard, from the MENU 2 screen, select the APPLICATIONS
screen. The APPLICATIONS screen will appear as shown in Figure 9-1.

Figure 9-1: Application Menu

Scroll to the RTCA/DO-160D entry using the up and down cursor keys. Press the ENTER key to
select the RTCA/DO 160D main menu. The screen will appear as shown in Figure 9-2.

Note: The user has to turn on the Output relay before starting a test.