AMETEK RS Series User Manual
Page 176
User Manual
AMETEK Programmable Power
RS Series
176
T1
0 Volt
F1
F2
T2
T3
Test no.
21(I)
22(II)
23(III)
24(IV)
25(V)
26(VI)
T1 (ms)
50
50
100
100
200
200
F1 (Hz)
360
Fmax
360
Fmax
360
Fmax
F2 (Hz)
Fmax
360
Fmax
360
Fmax
360
Fmax = 650 Hz for Group 2
Fmax = 800 Hz for Group 3
T2 = 20 msec
T3 = 5 msec
Figure 9-7: Power Interrupt for Group 2 and 3
VOLTAGE SURGE
This test requires 160 volt output voltage. If the power source is set at the low voltage range,
the high voltage range will be selected before the test starts. At the end of the test, the power
source will be switched back to the low range automatically
Voltage
Time
Seq. No.
RTCA
Group 1
Group 2
Group 3
ALL
1
115
115
115
115
5 Minute
2
160
160
160
170
30msec
3
115
115
115
115
5 Sec.
4
60
70
70
70
30msec
5
115
115
115
115
5 Sec.
Table 9-4: Normal VoltageSurge Sequence
The output voltage will follow the sequence in Table 9-4. The above sequence will repeat itself
three times. Each repeat will start from sequence two. US and Group 1 will run at 400 Hz.
Group 2 and Group 3 will run at 360 Hz and 650 Hz for Group 2 and 800 Hz for Group 3. The
frequency will return to the nominal setting when the test is completed. The
←
key (backspace)
will terminate the test at any time.