beautypg.com

AMETEK RS Series User Manual

Page 198

background image

User Manual

AMETEK Programmable Power

RS Series

198

9.5.4.3 RUNNING THE TEST

The test sequence used is a function of the EUT class. The end user needs to determine the
appropriate class of EUT. The test protocol is document in the IEC 61000-4-13 test standard.
For reference, the test flow charts are shown here. It is assumed that the end user has a copy of
the actual test standard however.

Start - Class 1/2

Determine appropriate test

configuration

Perform 8.2.1 Test

"Harmonic combination"

Flatcurve and Overswing

Any functional

anomalies?

No

No

Class 2

required?

'Meister

curve' required?

Any functional

anomalies?

Any functional

anomalies?

Any functional

anomalies?

Test Completed

FAIL

Record

Results

Test Completed

PASS

Record

Results

Yes

Yes

No

Perform 8.2.2 Test

"Frequency Sweep"

Perform 8.2.4 Test

"Meister Curve"

Perform 8.2.3 Test

"Individual Harmonics/

Interharmonics"

Yes

Yes

No

Yes

Yes

No

No

Figure 9-28: IEC 61000-4-13 Test Flowchart Class 1 and 2