User Manual

AMETEK Programmable Power

RS Series

14

Output Parameter

RS90

RS180

RS270

RS360

RS450

RS540

Maximum ambient temperate for full power operation at full-scale voltage is 35° C.

Constant Power Mode:

Operation at higher currents but constant power is possible from 80% of Voltage range (125% of
max. current) declining to 100% of maximum current at 100 % of voltage range for short periods
of time or at reduced ambient temperatures. (< 15 mins @ 30° C). See Figure 2-2 and Figure 2-
4.

AC Mode

RS90, per
phase
V Lo: 200A
V Hi: 100A

RS90, per
phase
V Lo: 400A
V Hi: 200A

RS90, per
phase
V Lo: 600A
V Hi: 300A

RS90, per
phase
V Lo: 800A
V Hi: 400A

RS90, per
phase
V Lo: 1000A
V Hi: 500A

RS90, per
phase
V Lo: 1200A
V Hi: 600A

DC Mode

AC+DC Mode

RS90, per
phase
V Lo: 100A
V Hi: 50A

RS90, per
phase
V Lo: 200A
V Hi: 100A

RS90, per
phase
V Lo: 300A
V Hi: 150A

RS90, per
phase
V Lo: 400A
V Hi: 200A

RS90, per
phase
V Lo: 500A
V Hi: 250A

RS90, per
phase
V Lo: 600A
V Hi: 300A

Note:

Current derates linearly from 50% of voltage range to 20% of specified current at 5% of voltage
range

Current Limit
Accuracy

0.5% of full scale

Current Limit mode

Programmable, CC or CV mode

Repetitive Peak Current

Note:

Maximum Peak Current shown. Value shown reflects absolute peak current protection level. This level may not be

reached under all load conditions. Depending on load conditions, peak current may max out at lower levels due to amplifier
output impedance.
Note:

A repetitive peak current limit function is provided which will generate a fault and shut off the power supply if the

peak current drawn by the load exceeds the maximum level for more than 30 seconds. During this time, the amplifier will
limit the peak current at a somewhat level above the maximum level but it is not allowable to run in this mode indefinitely.
This should provide sufficient time to ride through any startup/inrush load conditions.

AC Mode

RS90, per
phase
V Lo: 600A
V Hi: 300A

RS90, per
phase
V Lo: 1200A
V Hi: 600A

RS90, per
phase
V Lo: 1800A
V Hi: 900A

RS90, per
phase
V Lo: 2400A
V Hi: 1200A

RS90, per
phase
V Lo: 3000A
V Hi: 1500A

RS90, per
phase
V Lo: 3600A
V Hi: 1800A

Frequency

Range:

Standard:

16 Hz - 819.0 Hz (for –HV option range, 45 Hz – 819.0 Hz)

-LF option:

16 Hz - 500.0 Hz

-HF option:

16 Hz – 905 Hz

Resolution:

0.01 Hz

from 16.00 to 81.91 Hz

0.1 Hz

from 82.0 to 819.0 Hz

Accuracy:

± 0.01 %

±0.25 % for the FC option

Phase (3 phase mode)

Range:

Phase B/C relative to phase A
0.0 to 360.0°

Resolution:

0.1°

Accuracy:

16 Hz - 100 Hz: < 1.5°
100 Hz - 500 Hz: < 2°
> 500 Hz:

< 4°