beautypg.com

Afd - active format description, Active, Format – Adtec digital RD-70 (version 1.02.04) Manual User Manual

Page 53: Description

background image

Note: Encoder must support alignment for aligned audio feature.

The RD-70 automatically configures the audio engines upon acquisition of a program when
engines and sdi matrix are configured to ‘AUTO’. The audio is automatically output based
on ascending audio PID order from the selected program, not PMT order, to retain encoder
compatibilities. The left hand status panel of the Web UI shows current active SDI audio
output. Advanced configuration is available via the Audio tab for users that need to select
custom PID’s, disable audios, and duplicate audio pairs.

Dolby E line placement is handled automatically to meet Dolby Labs specification. Some
users may need custom line placement. If the customer Dolby E line placement selection is
out of specification, the RD will revert line placement to the automatic in range value.
Please see

table

in notes for Dolby E line placement recommendations.

Notes:

Encoder must support alignment for aligned audio feature.

Pass-through audio bit-rates are now displayed on the left hand status panel. Please
note that these are live calculated bit-rates and will not show a static number.

Dolby Labs - Dolby E recommended line position table

625

25

1080i

50

1080p

50

720p

50

525

29.97

1080i
59.94

1080p

59.94

720p

59.94

Earliest

8

13

26

17

12

18

35

23

Ideal -80us

11

19

37

25

13

21

42

28

Ideal +- 80us

12

21

42

28

14

24

47

32

Ideal +80us

13

23

103

31

16

26

52

35

Latest

30

53

105

70

26

48

95

63

Adtec Auto

19

30

42

35

19

30

47

40

AFD - Active Format Description

Active Format Description (AFD) contains aspect ratio and handling information utilized to
aid in picture presentation of downstream devices. This is used most often by down-
converters and set top boxes.

AFD carriage can be carried within a transport stream as a unique ANC PID (ancillary pid),
within the video elementary stream as SEI data (H264), or user data (MPEG2). The RD-70
does not support AFD via an ANC PID at this time.