beautypg.com

Cas menu, Menu – Adtec digital RD-70 (version 1.02.04) Manual User Manual

Page 28

background image

CAS Menu

Item

Function

Options

Mode

Configures the current decryption setting.

OFF
BISS_1
BISS_E_USER_ID_ON
E
BISS_E_USER_ID_TW
O

Clear Session Word

The session keys used for decryption.

[MODE BISS_1] uses a 12-digit
hexadecimal Clear Session Word.

user-defined using the

numeric keypad

Encrypted Session
Word

The 16-digit hexadecimal Encrypted
Session Word for use with BISS_E modes.

user-defined using the
numeric keypad

User ID One

Valid in Mode BISS_E_USER_ID_ONE
ONLY. The 14-digit hexadecimal User ID

(injected ID) used for decryption.

user-defined using the
numeric keypad

User ID Two

Valid in Mode BISS_E_USER_ID_ONE

ONLY. The 14-digit hexadecimal User ID
(injected ID) used for decryption.

user-defined using the

numeric keypad

TS Out Decrypt

The TS Out Decrypt configuration
determines if the ASI output should mirror

the selected input (OFF), thus preserving
any encrypted streams or if it should be

decrypted / free to air (ON).

OFF, the default configuration, is
recommended for users needing to

redistribute transport streams in their
original form. The decoder will decrypt /

decode the selected program with the
entered BISS key, but the ASI output will

remain unaltered.
ON is recommended for users needing to

redistribute the ASI output as a free to air
SPTS/MPTS. All programs will be

decrypted with the user entered BISS key.

OFF
ON