beautypg.com

Audio menu, Audio, Menu – Adtec digital RD-70 (version 1.02.04) Manual User Manual

Page 23

background image

Audio Menu

Item

Function

Options

Audio Assign
Order

The RD automatically assigns
audio PID's to audio engines
upon stream acquisition. This
setting determines if the audio
assignment should be done in
PID Ascending order, the Adtec
default, or PMT order. Some
legacy IRD's use PMT order.

PID ORDER (default)
PMT ORDER

Audio Sync
Mode

Audio Sync Mode determines
how the audio sub-system
should behave with incoming
transport streams. When it is
desired for the audio
subsystem to retain tight
lipsync and adjust on
upstream lip sync changes,
this should be configured for
Professional, the default
setting. In rare cases, third
party encoders or multiplexers
may have unstable PCR/PTS
timing. In these cases
professional may cause
intermittent drop outs as the
audio sub-system attempts to
retain tight lip sync. If this
occurs, please change lipsync
setting to Relaxed.

PROFESSIONAL (default)
RELAXED_20_MS
RELAXED_80_MS
RELAXED_1_S

Audio 1-8

Audio PID

Allows selection of available

audio PID associated with
program. note: Selection list

only shows PIDs listed in PMT.
Manual PID entry (such as IFB

applications) is only available
via the UI and SNMP at this

time.

DISABLED

AUTO (default)
* shows PID list from actively decoding

program

Offset Pair

Adjusts each individual pairs of

audio sync.

-50 - 800ms