Vbi menu, Profile menu, Menu profile – Adtec digital EN-30 (version 1.02.02) Manual User Manual
Page 25: Menu

Tltxt PID
Configures PID marked for
Teletext Packets
Hex value 0x0020 -
0x1FFE
*.ECMD# TPI
VITC Mode
Enables VITC Mode
OFF
ON
*.ECMD# BMO 1
VITC PID
Configures PID marked for
ANC / VITC Packets
Hex value 0x0020 -
0x1FFE
*.ECMD# BMI 1
Splice PID
Active
Enables Splice PID
OFF
ON
*.ECMD# RIT
Splice PID
Configures PID marked for
Splicing
Hex value 0x0020 -
0x1FFE
*.ECMD# SPI
Note:
No two PID’s may be configured for the same value with the exception of VIDEO and
PCR with MPEG2 encoder. The encoder does not accept PID values already assigned to
another elementary stream. Use the PDU command to get a ‘Program Dump’ of all assigned
PID’s. Adtec Digital encoders have the ability to process VBI waveform data and Ancillary
(SDI non video information), however they can't process both at the same time. If the
"VITC PID" option is turned on, waveform closed captions and teletext will not be able to be
processed.
VBI Menu
The following diagram illustrates the structure and flow of the VBI Menu on the Adtec EN-
30 device:
Control
Function
Options
API Command
VBI Source
VBI Source allows selection of
Composite or SDI for as vbi data source.
SDI
Composite
*.ECMD# VBS
Closed Caption
Closed Caption support includes
waveform caption processing, 608->708
up-conversion ( composite, SD-SDI ),
and ancillary 608/708 processing (
SD/HD-SDI ).
OFF
ATSC
ATSC Convert
ATSC 708
DVS 157
*.ECMD# CLC
Profile Menu
The following diagram illustrates the structure and flow of the Profile Menu on the Adtec
EN-30 device:
Control
Function
API Command
Select
Select a previously saved profile to RUN / LOAD as
the current configuration. Press
*.SYSD PROFILE