Front panel menu structure, Services menu, Front – Adtec digital EN-30 (version 1.02.02) Manual User Manual
Page 13: Panel, Menu, Structure, Services

Note: If the Modulator Frequency is reconfigured when Transmit = ENABLED, then Transmit
will be automatically set to DISABLED.
Front Panel Menu Structure
Services Menu
The following diagram illustrates the structure and flow of the Services Menu on the Adtec
EN-30 device. TX MUX Rate, Table, and TSID are global configurations, while items under
the denoted << >> parallel menu are unique to each encoder :
Control
Function
Options
API Command
TS MUX
Rate
Configures the total transport multiplex rate.
*Controlled by modulator when set to
Enable
1 - 150
Mb/s
*.ECMD0 TMR
Video
Autofill
Video Autofill automatically adjust the Video
Bit Rate to occupy the maximum fill of the
TS Mux Rate
ON
OFF
*.ECMD0 VAF
Tables
Configures the table generation standard to
be used
DVB
ATSC
MPEG
*.ECMD0 TON
TSID
Transport Stream ID is a user-defined value
in the PAT packet used to identify individual
transport streams
0x0000 -
0xFFFF
*.ECMD0 TSI
ASI Mode
Configures the encoder to egress a constant
transport stream when video is not present.
It is recommended to keep ASI Mode set to
Continuous
ON
OFF
*.ECMD0 ASM
ASI
Remux
Reserves the bandwidth needed for
incoming ASI transport stream
Note: Setting value to zero disables ASI
Remux
0-100
Mb/s
*.ECMD0 TRS
ASI 0
Active
Configure each encoding module to be
turned on or off
ON
OFF
*.ECMD# STU
Service
Name
Name of the program or event, carried in
the SDT table of a transport stream
text field;
20-
character
limit (incl.
spaces)
*.ECMD# SNA
Service
Provider
Name of the party offering the program or
event, carried in the SDT table of a
transport stream
text field;
20-
character
limit (incl.
*.ECMD# SPR