User’s Manual 174

4.

Example:

The following example specifies to enable reauthetication on the interface fe1
(port 1):

switch_a(config)#interface fe1
switch_a(config-if)#dot1x reauthentication
switch_a(config-if)#


Port Control:
1.

Command Mode: Interface mode

Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode.
fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen.

switch_a(config)#interface fe1
switch_a(config-if)#


2.

Usage:

Use this command to force a port state.
Use no dot1x port-control command to remove a port from the 802.1x
management.

3.

Command Syntax:

dot1x port-control auto|force-authorized|force-unauthorized
no dot1x port-control
auto Specify to enable authentication on port.
force-authorized Specify to force a port to always be in an authorized state.
force-unauthorized Specify to force a port to always be in an unauthorized

state.


4.

Example:

The following example specifies to enable authetication on the interface fe1
(port 1):

switch_a(config)#interface fe1
switch_a(config-if)#dot1x port-control auto
switch_a(config-if)#


Periodic Reauthentication:
Reauthentication Period:
1.

Command Mode: Interface mode

Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode.
fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen.

switch_a(config)#interface fe1