Hardened Managed PoE Ethernet Switch

User’s Manual 122

Alarm Setting
Alarm-trigger if:
1.

Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.

switch_a(config)#


2.

Usage:

Use this command to enable or disable alarm trigger on interface.

3.

Command Syntax:

(no) alarm-trigger if INTERFACE

INTERFACE specifies the interface.


4.

Example:

The following example enables alarm trigger on interface “fe1” to switch:

switch_a(config)#alarm-trigger if fe1
switch_a(config)#


Alarm-trigger power:
1.

Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.

switch_a(config)#


2.

Usage:

Use this command to enable or disable alarm trigger of power source.

3.

Command Syntax:

(no) alarm-trigger power POWER

POWER specifies the power source.


4.

Example:

The following example enables alarm trigger of power “1” to switch:

switch_a(config)#alarm-trigger power 1
switch_a(config)#


Reboot
1.

Command Mode: Privileged Exec mode

Logon to Privileged Exec Mode (Enable Mode).
The switch_a# prompt will show on the screen.

switch_a#


2.

Usage: