beautypg.com

Signamax Model -065-7700 User Manual

Page 167

background image

Hardened Managed PoE Ethernet Switch

User’s Manual 166

The switch_a(config)# prompt will show on the screen.

switch_a(config)#


2.

Usage:

Use snmp-server trap-type enable linkDown command to enable link
down trap for SNMP.
Use the no snmp-server trap-type enable linkDown command to disable
link down trap for SNMP.

3.

Command Syntax:

(no) snmp-server trap-type enable linkDown

4.

Example:

The following example enables link down trap for SNMP:

switch_a(config)#snmp-server trap-type enable linkDown
switch_a(config)#


Link Up Trap:
1.

Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.

switch_a(config)#


2.

Usage:

Use snmp-server trap-type enable linkUp command to enable link up trap
for SNMP.
Use the no snmp-server trap-type enable linkUp command to disable link
up trap for SNMP.

3.

Command Syntax:

(no) snmp-server trap-type enable linkUp

4.

Example:

The following example enables link up trap for SNMP:

switch_a(config)#snmp-server trap-type enable linkUp
switch_a(config)#


Authentication Failure Trap:
1.

Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.

switch_a(config)#


2.

Usage: