Signamax Model -065-7700 User Manual
Page 173

Hardened Managed PoE Ethernet Switch
User’s Manual 172
destination port number (1812):
switch_a(config)#radius-server host 192.168.1.100 auth-port 1812
switch_a(config)#
Secret Key:
1.
Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.
switch_a(config)#
2.
Usage:
Use this command to set the shared secret key between a Radius server and
a client.
3.
Command Syntax:
(no) radius-server host IP-ADDRESS key KEY
IP-ADDRESS A.B.C.D specifies the IP address of the radius server host.
KEY specifies the secret key shared among the radius server and the
802.1x client.
4.
Example:
The following example specifies the IP address (192.168.1.100) of the
remote radius server host and set the secret key (ipi) shared among the
radius server and the 802.1x client:
switch_a(config)#radius-server host 192.168.1.100 key ipi
switch_a(config)#
Timeout:
1.
Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.
switch_a(config)#
2.
Usage:
Use this command to specify the number of seconds a Switch waits for a
reply to a radius request before retransmitting the request.
3.
Command Syntax:
radius-server timeout SEC
no radius-server timeout
SEC <1-1000> The number of seconds for a Switch to wait for a server host
to reply before timing out. Enter a value in the range 1 to 1000.
4.
Example: