Signamax Model -065-7700 User Manual
Page 157

Hardened Managed PoE Ethernet Switch
User’s Manual 156
The following example sets the switchport mode trunk of the interface fe1
(port 1):
switch_a(config)#interface fe1
switch_a(config-if)#switchport mode trunk
switch_a(config-if)#
Switchport hybrid allowed vlan:
1.
Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode.
fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen.
switch_a(config)#interface fe1
switch_a(config-if)#
2.
Usage:
Use this command to set the switching characteristics of the Layer-2 interface
to hybrid. Both tagged and untagged frames will be classified over hybrid
interfaces.
Use the no parameter to turn off allowed hybrid switching.
3.
Command Syntax:
switchport hybrid allowed vlan all
switchport hybrid allowed vlan none
switchport hybrid allowed vlan add VLANID egress-tagged enable/disable
switchport hybrid allowed vlan remove VLANID
no switchport hybrid vlan
all Allow all VLANs to transmit and receive through the Layer-2 interface.
none Allow no VLANs to transmit and receive through the Layer-2 interface.
add Add a VLAN to the member set.
remove Remove a VLAN from the member set.
VLANID <2-4094> The ID of the VLAN or VLANs that will be added to, or
removed from, the Layer-2 interface.
For a VLAN range, specify two VLAN numbers: lowest, then highest
number in the range, separated by a hyphen.
For a VLAN list, specify the VLAN numbers separated by commas.
egress-tagged
enable Enable the egress tagging for the outgoing frames.
disable Disable the egress tagging for the outgoing frames.
4.
Example:
The following example specifies to add the interface fe1 (port 1) to VLANID
(2) and enable the egress-tagged for the outgoing frames on interface fe1
(port 1):
switch_a(config)#interface fe1
switch_a(config-if)#switchport hybrid allowed vlan add 2 egress-tagged enable