B: p, Ppendix, Ower – NEXCOM OPPC 1520T User Manual
Page 110: Onsumption, Power consumption measurement
Copyright © 2011 NEXCOM International Co., Ltd. All Rights Reserved.
95
OPPC 1520T/1720T User Manual
Appendix B: Power Consumption
A
ppendix
B: p
ower
C
onsumption
Power Consumption Measurement
Purpose
The purpose of the power consumption test is to verify the power dissipa-
tion of the system and the load of the power supply.
Test Equipment
1. PROVA CM-07 AC/DC CLAMP METER
2. Burn-in test ver: 2.0
Device Under Test
DUT: Sys #1
Test Procedure
1. Power up the DUT and then boot Windows XP.
2. Enter the standby mode (HDD power down).
3. Measure the power consumption and record it.
4. Run the Burn-in test program to apply 100% full loading.
5. Measure the power consumption and record it.
OPPC 1720T
+12V
+24V
+30V
Full-Loading Mode
3.45A
1.73A
1.39A
Total
41.4W
41.52W
41.7W
Standby Mode
0.93A
0.49A
0.41A
Total
11.16W
11.76W
12.3W
OPPC 1520T
+12V
+24V
+30V
Full-Loading Mode
2.15A
1.11A
0.91A
Total
25.8W
26.64W
27.3W
Standby Mode
0.89A
0.46A
0.39A
Total
10.68W
11.04W
11.7W