Power Consumption Measurement

Purpose
The purpose of the power consumption test is to verify the power dissipa-
tion of the system and the load of the power supply.

Test Equipment
1. PROVA CM-07 AC/DC CLAMP METER
2. Burn-in test ver: 2.0

Device Under Test
DUT: Sys #1

Test Procedure
1. Power up the DUT and then boot Windows XP.
2. Enter the standby mode (HDD power down).
3. Measure the power consumption and record it.
4. Run the Burn-in test program to apply 100% full loading.
5. Measure the power consumption and record it.

OPPC 1720T

+12V

+24V

+30V

Full-Loading Mode

3.45A

1.73A

1.39A

Total

41.4W

41.52W

41.7W

Standby Mode

0.93A

0.49A

0.41A

Total

11.16W

11.76W

12.3W

OPPC 1520T

+12V

+24V

+30V

Full-Loading Mode

2.15A

1.11A

0.91A

Total

25.8W

26.64W

27.3W

Standby Mode

0.89A

0.46A

0.39A

Total

10.68W

11.04W

11.7W